Centre for Dynamic Imaging

Bruker Skyscan 1276 Micro-CT

A high-resolution desktop in vivo micro-CT system with fast InstaRecon® 3D reconstruction software for preclinical imaging.

Micro computed tomography (micro-CT) is X-ray imaging in 3D. The SkyScan 1276 is a high-performance standalone in vivo micro-CT system that gives researchers flexible options for scanning preclinical models and biological samples. Non-destructive handling allows for longitudinal studies of the same sample.

The platform enables both round and spiral (helical) scanning and reconstruction, and low dose imaging for longitudinal studies.

Continuously variable magnification allows users to scan samples with high spatial resolution down to 2.8 μm pixel size.

Variable X-ray energy combined with a range of filters ensures optimal image quality for diverse research applications, including lung tissue and bone.

Hardware

Bruker Skyscan 1276 Micro-CT platform with:

  • 14-bit cooled digital X-ray CCD camera with fibre-optic coupling to scintillator
  • 20-100 kV micro-focus X-ray source
  • 6-positions automatic filter changer for energy selection
  • Integrated physiological monitoring
  • High end computer workstation and InstaRecon® reconstruction software

Technological specifications (capabilities)

  • X-ray source: continuous variable peak energy from 20 till 100kV, < 5 micron spot size at 4 watt; 20W maximum power, air cooled sealed type
  • X-ray detector: 11 Megapixel (4032 x 2688) 14-bit cooled digital X-ray CCD camera with 2×2, 4×4, 8×8 binning modes
  • 6-positions automatic filter changer for energy selection: no filter, Al 0.5mm, Al 1mm, Al 0.5mm + Cu 0.03mm, Cu 0.1mm and “low-dose” filter (beam shaper)
  • Image pixel size can be continuously adjusted from 2.8 μm till 10μm (full camera format) or up to 80μm (8×8 binning)
  • Integrated physiological monitoring (breathing, movement detection, ECG) and real-time motion detection (5 MP colour camera)

Unique features

  • Variable magnification with smallest pixel size of 2.8 micron, 5-6 micron details resolved with more than 10% contrast
  • Spiral scan using endless gantry rotation
  • Step-and-shoot and continuous gantry rotation with shortest scanning cycle of 3.9 sec
  • GPU-accelerated and world’s fastest InstaRecon® 3D reconstructions
  • Integrated physiological monitoring (breathing, movement detection, ECG) for gating and time-resolved 4D micro-tomography
  • Software for 2D/3D image analysis, bone morphology and realistic visualisation
Above: Bone sample imaged on the Bruker Skyscan 1276 Micro-CT. Credit: Raymond Yip
Above: Depth colour coded image of flower. Credit: Lachlan Whitehead

Limitations

  • Resolution is around 6 microns
  • This is not a multi-modality platform
  • Applications requiring lower doses of radiation will have reduced resolution
  • Contrast agents may be required if sample has low X-ray absorption

Related microscope

Experts

Professor Kelly Rogers
  • Head, Centre for Dynamic Imaging
Dr Lachlan Whitehead
  • Bioimage analyst
Contact us

Contact the Centre for Dynamic Imaging to book equipment or discuss imaging collaborations.